Many homeowners assume that simply turning off the water to the sprinkler system is enough to protect it through winter. The accurate answer is that you must remove water from the pipes, valves, and sprinkler heads, or freezing water will expand and crack them. Here’s the full step-by-step process to winterize your system safely and avoid costly spring repairs.
Why You Must Drain the System
When water freezes, it expands by about 9% by volume. In a closed sprinkler pipe, that expansion has nowhere to go, so it pushes against the pipe walls, causing cracks, splits, and burst fittings. Even a small amount of trapped water can damage PVC, polyethylene, or metal pipes. The goal of winterizing is to get the system as dry as possible before the first hard freeze.
The most reliable method is using an air compressor to blow out the lines, but you can also drain the system manually if your system is designed with drain valves. Both methods are covered below.
Before You Start: What You’ll Need
Gather these items before you begin, so you don’t have to stop mid-task:
- An air compressor (typically 10–20 CFM at 40–80 PSI for residential systems)
- A hose adapter to connect the compressor to the sprinkler system’s blow-out port
- Safety glasses and ear protection (compressor noise and debris)
- A wrench or pliers for opening valves and drain caps
- A bucket or towel for any water that drains out
Check your system’s manual if you have it—some systems have specific blow-out instructions. If you don’t have a manual, look for the main shut-off valve and the blow-out port, usually located near the backflow preventer or where the main line enters the house.
Step 1: Shut Off the Water Supply
Locate the main shut-off valve for your sprinkler system. This is usually a ball valve on the pipe that feeds the system from your home’s water supply. Turn it clockwise until it’s fully closed. This stops any new water from entering the system.
Next, open the test cocks (small valves) on the backflow preventer to relieve pressure. You may see water trickle out—that’s normal. Leave them open during the blow-out process.
Step 2: Drain the Backflow Preventer
The backflow preventer is the device that keeps your irrigation water from flowing back into your drinking water. It has two or more valves and small brass caps. After shutting off the water, open both test cocks fully. Then, use a flat-head screwdriver to open the small drain caps on the bottom of the backflow preventer. This lets water drain out. Leave the test cocks and drain caps open for the winter so any residual moisture can escape.
If your backflow preventer is above ground and exposed, consider wrapping it with insulation tape or a foam cover after draining, but only if the manufacturer allows it—some covers trap moisture and cause corrosion.
Step 3: Blow Out the Lines (Air Compressor Method)
This is the most thorough way to remove water from pipes, valves, and heads. If you’re not comfortable using an air compressor, you can hire a professional, but it’s a straightforward DIY task if you follow safety rules.
Connect the air compressor hose to the blow-out port (usually a threaded fitting on the main line near the backflow preventer). Set the compressor regulator to 40–80 PSI—never exceed 80 PSI, as it can damage fittings and heads. For systems with larger pipe (1.5 inches or more), you may need higher CFM, but pressure stays the same.
Close the backflow preventer’s test cocks and drain caps before blowing. Then, open the compressor’s valve to send air into the system. Work zone by zone: start with the zone farthest from the compressor, and open that zone’s valve (usually at the controller or manifold). Let air run until you see mist and then only air coming out of the sprinkler heads—this can take 1–3 minutes per zone. Then close that zone and move to the next. Repeat for every zone.
After all zones are done, close the compressor valve and disconnect the hose. Leave all zone valves closed and the main shut-off valve closed.
Step 4: Manual Drain Method (If No Compressor)
Some systems have manual drain valves at low points in the pipe. If your system has them, you can skip the compressor. After shutting off the water, open all the manual drain valves (usually small brass or plastic caps at the end of each pipe run). Let the water gravity-drain out. Then open the test cocks and backflow drain caps as described above.
This method works best if your pipes are sloped so water runs to the drains. If you have any low spots that don’t drain, you may still get freezing damage. In that case, consider hiring a professional to blow out the lines.
Step 5: Protect Above-Ground Components
After the lines are dry, cover the backflow preventer and any exposed valves with foam insulation covers or wrap them with insulation tape. These covers are available at hardware stores and are sized to fit standard backflow devices. Make sure the drain caps and test cocks are left open so any condensation can escape.
Also, check that all sprinkler heads are flush with the ground. If any head is sticking up, it can be damaged by lawn mowers or foot traffic. You can adjust them in spring, but for now, just ensure they’re not buried in dirt or leaves.
Signs Your System Was Damaged by Freezing
Even with careful winterizing, damage can occur. Look for these signs in early spring when you first turn the system on:
- Water pooling in the yard when a zone is on, indicating a cracked pipe
- Spraying water from the side of a head instead of the top
- Low water pressure at the heads
- Visible cracks in PVC pipes or fittings
- A hissing sound from the backflow preventer or valves
If you see any of these, shut off the water immediately and repair the damaged section. Minor cracks can be fixed with PVC primer and cement, but if you’re unsure, call an irrigation professional.
When to Winterize (and When to Wait)
The best time to winterize is about a week before the first hard freeze (temperatures below 32°F/0°C) is forecast. This gives you a buffer if the forecast changes. In most northern US regions, that’s between late September and early November. In warmer climates, you may not need to winterize at all if the ground never freezes.
If you have a smart controller, turn it off or set it to “rain mode” for the winter, but still blow out the lines—dormant systems still hold water.
Hiring a Professional vs. DIY
If you don’t own a compressor or are uncomfortable with the process, hiring a professional is a reasonable option. They typically charge a flat fee per zone and will also inspect for leaks. If you do it yourself, you save money but must be careful with the compressor—never leave it unattended while a zone is open, and always wear eye protection.
One common mistake is blowing out lines with too much pressure, which can blow the heads off. Stick to 40–80 PSI and you’ll be safe.
After you’ve winterized, make a note in your calendar to check the system in spring. When you reopen it, open the main valve slowly, then run each zone manually to check for leaks. With proper winterizing, your sprinkler system will last for years without freeze damage.
Spotted a mistake? Tell us and we will correct it. How we write and check articles.