Blow out drip irrigation lines when the average low temperature is forecast to stay below 32°F (0°C) for more than a few hours, usually in late fall before the first hard freeze. You do this because any water left in the lines can freeze, expand, and crack the emitters, fittings, and tubing. If your system is on a slope or has low spots, do it even earlier, before any overnight frost is predicted.
Why Freezing Damages Drip Lines
Water expands by about 9% when it turns to ice. In a drip line, that expansion pushes against the walls of thin polyethylene tubing and the small plastic emitters. A single freeze can split a fitting or pop an emitter right out of the line. Unlike sprinkler heads, drip emitters have tiny openings that ice can plug permanently, and the tubing itself can develop hairline cracks that leak for years.
The risk is highest in lines that run above ground, lie on the soil surface, or are buried less than 6 inches (15 cm) deep. Buried lines below the frost line—usually 12 inches (30 cm) or more in cold regions—may not need blowing out, but most home drip systems are surface-mounted or shallow, so assume yours needs it unless you know otherwise.
When Exactly to Do It
Blow out the lines after you have finished your last watering of the season, but before the first hard freeze. A hard freeze means temperatures at or below 28°F (-2°C) for several hours, which will freeze soil moisture and any standing water in the lines. In most of the northern US, that lands between mid-October and mid-November. In warmer zones where frost is rare, you can skip the blowout entirely if the ground never freezes.
Check a 10-day forecast. If nights are dipping into the upper 20s and you have not yet drained the system, do it that same day. It is better to blow out a week early than a day late. If you have a backflow preventer or pressure regulator, those components also hold water and can crack, so include them in the process.
How to Blow Out the Lines
You need an air compressor with a regulator that can be set to 40–50 psi (pounds per square inch) for drip systems—never go above 50 psi, or you will burst the tubing. If your compressor only has a trigger nozzle, you can use a blowout adapter that connects to the hose bib or the end of the mainline. Work in sections, not all at once.
- Turn off the water supply to the irrigation system.
- Open the end caps or flush valves on each drip line so air and water can escape.
- Connect the compressor to the mainline or to one zone at a time.
- Set the regulator to 40–50 psi and open the air valve slowly.
- Let air run until water stops spraying out of the open ends, then continue for another 30 seconds to push out remaining droplets.
- Close that zone’s valve, move to the next zone, and repeat.
- When all zones are dry, remove the end caps and leave them off for winter.
Do not run the compressor unattended. Watch the pressure gauge constantly; if it spikes, shut off the air immediately. If a line has a filter, remove the filter cartridge and let it dry indoors, then reinstall it in spring.
Worked Example: A 4-Zone System
Suppose you have four zones, each with a 50-foot (15 m) run of 1/2-inch drip tubing. With the compressor set at 45 psi, each zone takes about 2 minutes to clear, plus 1 minute to move the hose and open the next valve. Total time: 4 zones × 3 minutes = 12 minutes. Add 5 minutes to drain the mainline and remove end caps. You are done in under 20 minutes.
What Happens If You Skip It
If you leave water in the lines and a hard freeze hits, you will likely find cracked fittings and split tubing in spring. The damage may not be visible until you turn the water on and see leaks or uneven flow. Replacing a single emitter is easy, but a split mainline can mean digging up a section of your garden. In mild climates where the ground never freezes, skipping the blowout is fine—just drain the lines by opening the end caps and letting gravity do the work.
One common mistake is blowing out the lines too early, then forgetting to drain the mainline or leaving the end caps off. If you blow out in October and then get a warm spell, you might want to water again. That is fine—just repeat the blowout before the next freeze. Another mistake is using too much pressure. Anything above 50 psi can blow apart the fittings, so always set the regulator first and test it on a spare piece of tubing if you are unsure.
Alternative: Gravity Drainage for Mild Winters
If your winters stay above freezing, you do not need a compressor. Simply open all end caps and flush valves, lift any low spots in the tubing so water runs downhill, and let the lines sit open for a few hours. This works for systems on a slope or where you can easily disconnect the supply. It will not remove every drop, but if the temperature never drops below 32°F, leftover water is harmless.
For systems with a backflow preventer, drain that separately by opening the test cocks or unscrewing the unit and tipping it over. Store it indoors if it is the type with plastic internal parts. In spring, before you reconnect everything, flush each line with water for a minute to clear out any debris that settled over winter.
If you are unsure whether your area gets hard freezes, check your local frost dates or ask a neighbor who gardens. When in doubt, blow out the lines—it takes 20 minutes and costs nothing but a little electricity for the compressor.
Spotted a mistake? Tell us and we will correct it. How we write and check articles.